ASTM A262 PRACTICE E PDF

ASTM A262 PRACTICE E PDF

Abstract. A detailed study of AISI and stainless steels (SSs) has been conducted to correlate the degree of sensitization (DOS) measured by the. ASTM a Test, Intergranular Corrosion, IGC, ASTM A Practice, Copper – Copper Sulfate – 16% sulfuric acid, ASTM A – Practice E (Strauss Test). ASTM A Practice E test. This practice describes the procedure by which the copper-copper sulfate% sulfuric acid test is conducted to determine .

Author: Voodoorg Akinojinn
Country: Cameroon
Language: English (Spanish)
Genre: Environment
Published (Last): 12 August 2004
Pages: 74
PDF File Size: 3.9 Mb
ePub File Size: 2.35 Mb
ISBN: 199-7-29281-309-8
Downloads: 3490
Price: Free* [*Free Regsitration Required]
Uploader: Vukazahn

This website uses cookies to improve user experience. By using our website you consent to all cookies in accordance with our Cookie Policy.

ASTM A is a common intergranular corrosion testing method that can quickly screen batches of material to determine corrosion susceptibility.

Choosing the correct method s rely on a complete understanding of your material and processes, as well as the concept of corrosion itself.

To understand intergranular corrosion testing or intergranular attack commonly abbreviated as IGC or IGAit is important to understand what causes the process to occur. Metals like stainless steels and aluminum contain elements such as niobium and chromium, often integrated because of their natural corrosion resistance.

However, when a material is exposed to high temperatures for long periods of time, a process called sensitization may occur. Sensitization causes the grain boundaries of a material to precipitate, creating carbide deposits and causing the material to be susceptible to intergranular attack. Since high temperature processing such as heat treatment is a common practice, many manufacturers wish to perform intergranular corrosion qualification testing on each batch, to ensure that the material has been processed correctly and does not show signs of corrosion susceptibility.

  1N5352 DATASHEET PDF

ASTM A testing is a popular method of choice due to the variety of practices available and the relatively short turnaround for results. All five methods within this specification involve exposing specimens to a chemical mixture designed to encourage corrosive behavior. At the conclusion off the test, specimens are either visually examined or measured for weight loss and compared to an established corrosion rate for that specific material type.

Intergranular Corrosion Testing: An Overview of ASTM A262

This simple etching technique is used as a quick screening method to ensure that a material is free of intergranular corrosion susceptibility. The Oxalic Acid test is only used to ensure that no corrosion exists; samples are labeled either “Acceptable” or “Suspect”. A different ASTM A test method must be used to quantify the level of corrosion or to disqualify a material for use. The Oxalic Acid test is also only applicable to corrosion associated with chromium carbide precipitates and is only useful for specific material grades.

Please refer to the specification for more details.

ASTM A Intergranular Corrosion Testing and Analysis

The level of corrosion is determined by mass loss. Similar to the Streicher test, the Huey test method uses a nitric acid solution and subjects the specimen to five hour boiling intervals. The samples are weighed at each interval to determine mass loss and degree of susceptibility to intergranular attack. sstm

This method is preferable for chromium depletions and corrosion in intermetallic phases. This test is used exclusively to determine corrosion in areas high in chromium carbide formations, and is not as effective for aa262 attack caused by other means.

  AMLIE NOTHOMB LE SABOTAGE AMOUREUX PDF

Strauss test specimens are boiled in a Copper Sulfate – Sulfuric Acid mixture for 15 hours.

A bend test followed by a visual or micro-examination are used to determine “Pass” or “Fail” of pgactice specimens. This method is a hour boiling test for “as received” specimens of stainless steel. The Copper Sulfate Test is especially effective for determining susceptibility to intergranular attack for low carbon steels.

Our knowledgeable scientists have the experience and expertise necessary to determine the most appropriate intergranular attack testing methods for your material while providing actionable results you can rely on. View more articles about Aerospace Oil and Gas Transportation. We provide intergranular corrosion evaluation, salt spray testing, stress corrosion, and various other methods to simulate exposure of your products or materials to corrosive environments.

ASTM A Testing: An Overview of Intergranular Corrosion | Element

From macroscopic imaging to Scanning Electron Microscopy, Element provides a2662 metallographic services using state-of-the-art equipment.

Learn more about our laboratories – where they are located; the unique capabilities they have and how they can help you solve your technical and commercial challenges. Discover perspectives, resources, and advice from our world-leading Engaged Experts. Choosing an Intergranular Corrosion Test Method Since high temperature processing such as heat treatment is a common practice, many manufacturers wish to perform intergranular corrosion qualification testing on each batch, to ensure that the material has been processed correctly and does not show signs of corrosion susceptibility.