ASTM F146 PDF

ASTM F146 PDF

F – 80 Standard Test Methods for Fluid Resistance Of Gasket Materials. Designation: F – Standard Test Methods for. Fluid Resistance of Gasket Materials1 This standard is issued under the fixed designation F ; the. ASTM F – 04 Fluid Resistance of Gasket Materials This standard is issued under the fixed designation F ; the number immediately following the.

Author: Ararn Mazshura
Country: Belize
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 9 February 2005
Pages: 163
PDF File Size: 9.35 Mb
ePub File Size: 18.94 Mb
ISBN: 966-5-28427-957-7
Downloads: 67141
Price: Free* [*Free Regsitration Required]
Uploader: Kazrahn

Thank you for interesting in our services. We are a non-profit group that run this website to share documents.

We need your help to maintenance this website. Please help us to share our service with your friends. F — 04 Standard Test Methods for Fluid Resistance of Gasket Materials1 This standard is issued under the fixed designation F ; the number immediately following the designation indicates the year of original adoption or, in the case g146 revision, the year of last revision.

A number in parentheses indicates the year of last reapproval. A superscript epsilon e indicates an editorial change since the last revision or reapproval.

ASTM F – 01 Standard Test Methods for Fluid Resistance of Gasket Materials

This standard has been approved for use by agencies of the Department of Defense. These test methods are not applicable to the testing of f164 rubber, a procedure that is described in Test Method D It is designed for testing specimens cut from gasketing materials or from finished articles of commerce.

The inch-pound units in parentheses are for information only.

It is the responsibility of the user of satm standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Summary of Test Methods 3. After immersing the specimens in the various test fluids, the effect on physical properties is expressed as change in tensile strength, compressibility in softened condition, flexibility, volume change, and thickness and weight changes from the original condition.

Significance and Use 4. The results of these test methods are not intended to give any direct correlation with service conditions in view of the wide variations in temperature and special uses encountered in gasket applications. The specific test fluids and test conditions outlined were selected as typical for purposes of comparing asttm materials and can be used as a routine test when agreed upon between the purchaser and the manufacturer.

  KARZMARK LINEAR ACCELERATOR PDF

Satm edition approved April 1, Originally approved in Last previous edition approved in as F — Dead weight loads are listed in Table 1. Temperature of Test Measurement 7. These test methods are applicable to ethylene glycol, propylene glycol, commercial coolants and blends with water thereof see Note 1water, and other commercial oils and fuels.

The producer must be aware that different coolant mixtures may yield different results. Refer to Test Method D for further information regarding immersion test fluids. BoxTrenton, NJ The user should be aware that results may differ.

NOTE 1—Coolant mixtures are typically tested under boiling reflux conditions. Graduate the dial in 0.

ASTM F146 – 12

The anvil shall have a diameter not less than that of the presser foot, which has a f164 of 6. Take a sufficient aetm of readings, depending on the size of the specimen, to wstm a reliable average value. Measure the weight of the test specimen to the nearest 1 mg 0. Pour enough fresh fluid into the tube to completely cover the specimens and ensure that they are immersed.

Insert the aluminum-foil covered stoppers into the test tubes before placing them in the supporting rack within the oven. Then withdraw the specimens from the cooled-down test fluid and immediately blot the samples with sheets of blotting paper to remove excess liquid from the surfaces.

Exercise care when removing the excess fluid so that no squeezing action occurs on the sample. Pour enough fresh test fluid over the specimens to ensure that the specimens are wetted and covered by the fluid.

Use enough fluid to provide a minimum of 10 mL for each specimen in the container. If such information is not available, then the material should be tested by itself in fresh fluid to determine compatibility with said fluid. The change in thickness of the specimens is to be calculated as an expression of percentage change from the original thickness.

NOTE 2—Great care must be taken to record the swollen thickness when the needle slows to a different rate which reflects indentation into the softened specimen. For materials having less than specific gravity 1. This gives the final volume, V2. Change the distilled water used in the test frequently. Use the same sinker throughout. The change in weight of the satm is to f1146 calculated as an expression of percentage change on the astn weight.

  LBC 3090 31 PDF

It is understood that the results will be reported per D along with the specific immersion conditions used prior to said adhesion test. Other physical property tests described in this standard are not applicable for these materials.

Type 1 Class ast BA material, containing a normally lower swelling polymer. Precision and Bias 7 There were six Type 1,7, three Type 3, and one Type 5 material evaluated for immersion weight change and thickness change in IRM oil.

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below.

Please fill this form, we will try to respond as soon as possible.

Please copy and paste this embed script to where you want to embed Embed Script. Size px x x x x We need your help!